Serveur d'exploration sur l'oranger

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Analysis of orange juice for total cysteine and glutathione content by CZE with UV-absorption detection.

Identifieur interne : 000940 ( PubMed/Curation ); précédent : 000939; suivant : 000941

Analysis of orange juice for total cysteine and glutathione content by CZE with UV-absorption detection.

Auteurs : Paweł Kubalczyk [Pologne] ; Edward Bald

Source :

RBID : pubmed:19569125

English descriptors

Abstract

For total content of cysteine (Cys) and glutathione (GSH) a sample (500 microL) of neat orange juice or commercially available soft drinks is treated according to the procedure consisted of four essential steps: reduction of disulfide forms of the analytes to their thiol counterparts with Tris 2-carboxyethylphosphine, derivatization of thiols to their S-quinolinium derivatives with 2-chloro-1-methylquinolinium tetrafluroborate, separation of so-formed derivatives by capillary zone electrophoresis with ACN stacking, and detection and quantitation with the use of ultraviolet detector at 355 nm. Commercially available bare fused-silica capillary served as the CE column. The method is linear in a wide range of concentrations covering practical application. The coefficient of correlation between analyte concentrations within the range from 2.5 to 30.0 micromol/L and the detector response was for Cys and GSH 0.998 and 0.997, respectively. The imprecision for above-mentioned range was between 6.7 and 3.8, and 3.6 and 1.1% RSD for Cys and GSH, respectively. The method was applied to several samples of fresh juices and commercial orange beverages.

DOI: 10.1002/elps.200800741
PubMed: 19569125

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:19569125

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Analysis of orange juice for total cysteine and glutathione content by CZE with UV-absorption detection.</title>
<author>
<name sortKey="Kubalczyk, Pawel" sort="Kubalczyk, Pawel" uniqKey="Kubalczyk P" first="Paweł" last="Kubalczyk">Paweł Kubalczyk</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Environmental Chemistry, University of Łódź, Łódź, Poland.</nlm:affiliation>
<country xml:lang="fr">Pologne</country>
<wicri:regionArea>Department of Environmental Chemistry, University of Łódź, Łódź</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Bald, Edward" sort="Bald, Edward" uniqKey="Bald E" first="Edward" last="Bald">Edward Bald</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2009">2009</date>
<idno type="RBID">pubmed:19569125</idno>
<idno type="pmid">19569125</idno>
<idno type="doi">10.1002/elps.200800741</idno>
<idno type="wicri:Area/PubMed/Corpus">000940</idno>
<idno type="wicri:Area/PubMed/Curation">000940</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Analysis of orange juice for total cysteine and glutathione content by CZE with UV-absorption detection.</title>
<author>
<name sortKey="Kubalczyk, Pawel" sort="Kubalczyk, Pawel" uniqKey="Kubalczyk P" first="Paweł" last="Kubalczyk">Paweł Kubalczyk</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Environmental Chemistry, University of Łódź, Łódź, Poland.</nlm:affiliation>
<country xml:lang="fr">Pologne</country>
<wicri:regionArea>Department of Environmental Chemistry, University of Łódź, Łódź</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Bald, Edward" sort="Bald, Edward" uniqKey="Bald E" first="Edward" last="Bald">Edward Bald</name>
</author>
</analytic>
<series>
<title level="j">Electrophoresis</title>
<idno type="eISSN">1522-2683</idno>
<imprint>
<date when="2009" type="published">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acetonitriles (chemistry)</term>
<term>Beverages (analysis)</term>
<term>Chromatography, High Pressure Liquid</term>
<term>Citrus sinensis (chemistry)</term>
<term>Cysteine (analysis)</term>
<term>Electrophoresis, Capillary (methods)</term>
<term>Fruit (chemistry)</term>
<term>Glutathione (analysis)</term>
<term>Reproducibility of Results</term>
<term>Sensitivity and Specificity</term>
<term>Ultraviolet Rays</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="analysis" xml:lang="en">
<term>Cysteine</term>
<term>Glutathione</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en">
<term>Acetonitriles</term>
</keywords>
<keywords scheme="MESH" qualifier="analysis" xml:lang="en">
<term>Beverages</term>
</keywords>
<keywords scheme="MESH" qualifier="chemistry" xml:lang="en">
<term>Citrus sinensis</term>
<term>Fruit</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Electrophoresis, Capillary</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Chromatography, High Pressure Liquid</term>
<term>Reproducibility of Results</term>
<term>Sensitivity and Specificity</term>
<term>Ultraviolet Rays</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">For total content of cysteine (Cys) and glutathione (GSH) a sample (500 microL) of neat orange juice or commercially available soft drinks is treated according to the procedure consisted of four essential steps: reduction of disulfide forms of the analytes to their thiol counterparts with Tris 2-carboxyethylphosphine, derivatization of thiols to their S-quinolinium derivatives with 2-chloro-1-methylquinolinium tetrafluroborate, separation of so-formed derivatives by capillary zone electrophoresis with ACN stacking, and detection and quantitation with the use of ultraviolet detector at 355 nm. Commercially available bare fused-silica capillary served as the CE column. The method is linear in a wide range of concentrations covering practical application. The coefficient of correlation between analyte concentrations within the range from 2.5 to 30.0 micromol/L and the detector response was for Cys and GSH 0.998 and 0.997, respectively. The imprecision for above-mentioned range was between 6.7 and 3.8, and 3.6 and 1.1% RSD for Cys and GSH, respectively. The method was applied to several samples of fresh juices and commercial orange beverages.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">19569125</PMID>
<DateCreated>
<Year>2009</Year>
<Month>7</Month>
<Day>27</Day>
</DateCreated>
<DateCompleted>
<Year>2009</Year>
<Month>11</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1522-2683</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>30</Volume>
<Issue>13</Issue>
<PubDate>
<Year>2009</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>Electrophoresis</Title>
<ISOAbbreviation>Electrophoresis</ISOAbbreviation>
</Journal>
<ArticleTitle>Analysis of orange juice for total cysteine and glutathione content by CZE with UV-absorption detection.</ArticleTitle>
<Pagination>
<MedlinePgn>2280-3</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1002/elps.200800741</ELocationID>
<Abstract>
<AbstractText>For total content of cysteine (Cys) and glutathione (GSH) a sample (500 microL) of neat orange juice or commercially available soft drinks is treated according to the procedure consisted of four essential steps: reduction of disulfide forms of the analytes to their thiol counterparts with Tris 2-carboxyethylphosphine, derivatization of thiols to their S-quinolinium derivatives with 2-chloro-1-methylquinolinium tetrafluroborate, separation of so-formed derivatives by capillary zone electrophoresis with ACN stacking, and detection and quantitation with the use of ultraviolet detector at 355 nm. Commercially available bare fused-silica capillary served as the CE column. The method is linear in a wide range of concentrations covering practical application. The coefficient of correlation between analyte concentrations within the range from 2.5 to 30.0 micromol/L and the detector response was for Cys and GSH 0.998 and 0.997, respectively. The imprecision for above-mentioned range was between 6.7 and 3.8, and 3.6 and 1.1% RSD for Cys and GSH, respectively. The method was applied to several samples of fresh juices and commercial orange beverages.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kubalczyk</LastName>
<ForeName>Paweł</ForeName>
<Initials>P</Initials>
<AffiliationInfo>
<Affiliation>Department of Environmental Chemistry, University of Łódź, Łódź, Poland.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Bald</LastName>
<ForeName>Edward</ForeName>
<Initials>E</Initials>
</Author>
</AuthorList>
<Language>ENG</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Electrophoresis</MedlineTA>
<NlmUniqueID>8204476</NlmUniqueID>
<ISSNLinking>0173-0835</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000097">Acetonitriles</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>GAN16C9B8O</RegistryNumber>
<NameOfSubstance UI="D005978">Glutathione</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>K848JZ4886</RegistryNumber>
<NameOfSubstance UI="D003545">Cysteine</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>Z072SB282N</RegistryNumber>
<NameOfSubstance UI="C032159">acetonitrile</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000097" MajorTopicYN="N">Acetonitriles</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001628" MajorTopicYN="N">Beverages</DescriptorName>
<QualifierName UI="Q000032" MajorTopicYN="Y">analysis</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D002851" MajorTopicYN="N">Chromatography, High Pressure Liquid</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D032084" MajorTopicYN="N">Citrus sinensis</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="Y">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003545" MajorTopicYN="N">Cysteine</DescriptorName>
<QualifierName UI="Q000032" MajorTopicYN="Y">analysis</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019075" MajorTopicYN="N">Electrophoresis, Capillary</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005638" MajorTopicYN="N">Fruit</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="Y">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005978" MajorTopicYN="N">Glutathione</DescriptorName>
<QualifierName UI="Q000032" MajorTopicYN="Y">analysis</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012680" MajorTopicYN="N">Sensitivity and Specificity</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014466" MajorTopicYN="N">Ultraviolet Rays</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2009</Year>
<Month>7</Month>
<Day>2</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2009</Year>
<Month>7</Month>
<Day>2</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2009</Year>
<Month>11</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">19569125</ArticleId>
<ArticleId IdType="doi">10.1002/elps.200800741</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Bois/explor/OrangerV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000940 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000940 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Bois
   |area=    OrangerV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:19569125
   |texte=   Analysis of orange juice for total cysteine and glutathione content by CZE with UV-absorption detection.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:19569125" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a OrangerV1 

Wicri

This area was generated with Dilib version V0.6.25.
Data generation: Sat Dec 3 17:11:04 2016. Site generation: Wed Mar 6 18:18:32 2024