Serveur d'exploration sur l'oranger

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Stereospecific high-performance liquid chromatographic assay of isosakuranetin in rat urine☆

Identifieur interne : 000A63 ( Pmc/Corpus ); précédent : 000A62; suivant : 000A64

Stereospecific high-performance liquid chromatographic assay of isosakuranetin in rat urine☆

Auteurs : Karina R. Vega-Villa ; Connie M. Remsberg ; Kristy L. Podelnyk ; Neal M. Davies

Source :

RBID : PMC:2917051

Abstract

A stereospecific method of analysis of racemic isosakuranetin (5,7-dihydroxy-4′-methoxyflavanone) in biological fluids is necessary to study pharmacokinetics. A simple high-performance liquid chromatographic method was developed for the determination of isosakuranetin enantiomers. Separation was achieved on a Chiralpak® AD™-RH column with ultraviolet (UV)-detection at 286 nm. The standard curves in urine were linear ranging from 0.5 to 100.0 µg/ml for each enantiomer. The mean extraction efficiency was >88.0%. Precision of the assay was <15% (CV) and was within 12% at the limit of quantitation (0.5 µg/ml). Bias of the assay was <15% and was within 6% at the limit of quantitation. The assay was applied successfully to stereospecific disposition of isosakuranetin enantiomers in rat urine.


Url:
DOI: 10.1016/j.jchromb.2008.05.018
PubMed: 18514595
PubMed Central: 2917051

Links to Exploration step

PMC:2917051

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Stereospecific high-performance liquid chromatographic assay of isosakuranetin in rat urine
<xref ref-type="fn" rid="FN1"></xref>
</title>
<author>
<name sortKey="Vega Villa, Karina R" sort="Vega Villa, Karina R" uniqKey="Vega Villa K" first="Karina R." last="Vega-Villa">Karina R. Vega-Villa</name>
</author>
<author>
<name sortKey="Remsberg, Connie M" sort="Remsberg, Connie M" uniqKey="Remsberg C" first="Connie M." last="Remsberg">Connie M. Remsberg</name>
</author>
<author>
<name sortKey="Podelnyk, Kristy L" sort="Podelnyk, Kristy L" uniqKey="Podelnyk K" first="Kristy L." last="Podelnyk">Kristy L. Podelnyk</name>
</author>
<author>
<name sortKey="Davies, Neal M" sort="Davies, Neal M" uniqKey="Davies N" first="Neal M." last="Davies">Neal M. Davies</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">18514595</idno>
<idno type="pmc">2917051</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2917051</idno>
<idno type="RBID">PMC:2917051</idno>
<idno type="doi">10.1016/j.jchromb.2008.05.018</idno>
<date when="2008">2008</date>
<idno type="wicri:Area/Pmc/Corpus">000A63</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Stereospecific high-performance liquid chromatographic assay of isosakuranetin in rat urine
<xref ref-type="fn" rid="FN1"></xref>
</title>
<author>
<name sortKey="Vega Villa, Karina R" sort="Vega Villa, Karina R" uniqKey="Vega Villa K" first="Karina R." last="Vega-Villa">Karina R. Vega-Villa</name>
</author>
<author>
<name sortKey="Remsberg, Connie M" sort="Remsberg, Connie M" uniqKey="Remsberg C" first="Connie M." last="Remsberg">Connie M. Remsberg</name>
</author>
<author>
<name sortKey="Podelnyk, Kristy L" sort="Podelnyk, Kristy L" uniqKey="Podelnyk K" first="Kristy L." last="Podelnyk">Kristy L. Podelnyk</name>
</author>
<author>
<name sortKey="Davies, Neal M" sort="Davies, Neal M" uniqKey="Davies N" first="Neal M." last="Davies">Neal M. Davies</name>
</author>
</analytic>
<series>
<title level="j">Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</title>
<idno type="ISSN">1570-0232</idno>
<idno type="eISSN">1873-376X</idno>
<imprint>
<date when="2008">2008</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p id="P1">A stereospecific method of analysis of racemic isosakuranetin (5,7-dihydroxy-4′-methoxyflavanone) in biological fluids is necessary to study pharmacokinetics. A simple high-performance liquid chromatographic method was developed for the determination of isosakuranetin enantiomers. Separation was achieved on a Chiralpak
<sup>®</sup>
AD™-RH column with ultraviolet (UV)-detection at 286 nm. The standard curves in urine were linear ranging from 0.5 to 100.0 µg/ml for each enantiomer. The mean extraction efficiency was >88.0%. Precision of the assay was <15% (CV) and was within 12% at the limit of quantitation (0.5 µg/ml). Bias of the assay was <15% and was within 6% at the limit of quantitation. The assay was applied successfully to stereospecific disposition of isosakuranetin enantiomers in rat urine.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article" xml:lang="EN">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<pmc-dir>properties manuscript</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-journal-id">101139554</journal-id>
<journal-id journal-id-type="pubmed-jr-id">27040</journal-id>
<journal-id journal-id-type="nlm-ta">J Chromatogr B Analyt Technol Biomed Life Sci</journal-id>
<journal-title>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</journal-title>
<issn pub-type="ppub">1570-0232</issn>
<issn pub-type="epub">1873-376X</issn>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">18514595</article-id>
<article-id pub-id-type="pmc">2917051</article-id>
<article-id pub-id-type="doi">10.1016/j.jchromb.2008.05.018</article-id>
<article-id pub-id-type="manuscript">NIHMS217983</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Stereospecific high-performance liquid chromatographic assay of isosakuranetin in rat urine
<xref ref-type="fn" rid="FN1"></xref>
</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Vega-Villa</surname>
<given-names>Karina R.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Remsberg</surname>
<given-names>Connie M.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Podelnyk</surname>
<given-names>Kristy L.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Davies</surname>
<given-names>Neal M.</given-names>
</name>
<xref ref-type="corresp" rid="cor1">*</xref>
</contrib>
<aff id="A1">College of Pharmacy, Department of Pharmaceutical Sciences and Pharmacology Toxicology Graduate Program, Washington State University, Pullman, Washington 99164-6534, USA</aff>
</contrib-group>
<author-notes>
<corresp id="cor1">
<label>*</label>
Corresponding author. Tel.: +1 509 335 4754; fax: +1 509 335 5902.
<email>ndavies@wsu.edu</email>
(N.M. Davies)</corresp>
</author-notes>
<pub-date pub-type="nihms-submitted">
<day>27</day>
<month>7</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="ppub">
<day>1</day>
<month>11</month>
<year>2008</year>
</pub-date>
<pub-date pub-type="pmc-release">
<day>6</day>
<month>8</month>
<year>2010</year>
</pub-date>
<volume>875</volume>
<issue>1</issue>
<fpage>142</fpage>
<lpage>147</lpage>
<permissions>
<copyright-statement>© 2008 Elsevier B.V. All rights reserved.</copyright-statement>
<copyright-year>2008</copyright-year>
</permissions>
<abstract>
<p id="P1">A stereospecific method of analysis of racemic isosakuranetin (5,7-dihydroxy-4′-methoxyflavanone) in biological fluids is necessary to study pharmacokinetics. A simple high-performance liquid chromatographic method was developed for the determination of isosakuranetin enantiomers. Separation was achieved on a Chiralpak
<sup>®</sup>
AD™-RH column with ultraviolet (UV)-detection at 286 nm. The standard curves in urine were linear ranging from 0.5 to 100.0 µg/ml for each enantiomer. The mean extraction efficiency was >88.0%. Precision of the assay was <15% (CV) and was within 12% at the limit of quantitation (0.5 µg/ml). Bias of the assay was <15% and was within 6% at the limit of quantitation. The assay was applied successfully to stereospecific disposition of isosakuranetin enantiomers in rat urine.</p>
</abstract>
<kwd-group>
<kwd>HPLC</kwd>
<kwd>UV-detection</kwd>
<kwd>Stereospecific</kwd>
<kwd>Enantiomer</kwd>
<kwd>Flavonoid</kwd>
</kwd-group>
<contract-num rid="GM1">T32 GM008336-18 ||GM</contract-num>
<contract-num rid="GM1">T32 GM008336-17 ||GM</contract-num>
<contract-num rid="GM1">T32 GM008336-16 ||GM</contract-num>
<contract-sponsor id="GM1">National Institute of General Medical Sciences : NIGMS</contract-sponsor>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Bois/explor/OrangerV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000A63 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000A63 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Bois
   |area=    OrangerV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:2917051
   |texte=   Stereospecific high-performance liquid chromatographic assay of isosakuranetin in rat urine☆
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:18514595" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a OrangerV1 

Wicri

This area was generated with Dilib version V0.6.25.
Data generation: Sat Dec 3 17:11:04 2016. Site generation: Wed Mar 6 18:18:32 2024