Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique.
Identifieur interne : 000071 ( PubMed/Curation ); précédent : 000070; suivant : 000072Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique.
Auteurs : Yannick Herry [France] ; Cécile Batailler [France] ; Timothy Lording [Australie] ; Elvire Servien [France] ; Philippe Neyret [France] ; Sebastien Lustig [France]Source :
- International orthopaedics [ 1432-5195 ] ; 2017.
Abstract
Joint-line restitution is one objective of unicompartmental knee arthroplasty (UKA). However, the joint line is often lowered when resurfacing femoral implants are used. The aim of this study was to compare the joint-line height in UKA performed by robotic-assisted and conventional techniques.
DOI: 10.1007/s00264-017-3633-9
PubMed: 28913557
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000071
Links to Exploration step
pubmed:28913557Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique.</title>
<author><name sortKey="Herry, Yannick" sort="Herry, Yannick" uniqKey="Herry Y" first="Yannick" last="Herry">Yannick Herry</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Batailler, Cecile" sort="Batailler, Cecile" uniqKey="Batailler C" first="Cécile" last="Batailler">Cécile Batailler</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Lording, Timothy" sort="Lording, Timothy" uniqKey="Lording T" first="Timothy" last="Lording">Timothy Lording</name>
<affiliation wicri:level="1"><nlm:affiliation>Melbourne Orthopaedic Group, Melbourne, VIC, Australia.</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>Melbourne Orthopaedic Group, Melbourne, VIC</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Servien, Elvire" sort="Servien, Elvire" uniqKey="Servien E" first="Elvire" last="Servien">Elvire Servien</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Neyret, Philippe" sort="Neyret, Philippe" uniqKey="Neyret P" first="Philippe" last="Neyret">Philippe Neyret</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Lustig, Sebastien" sort="Lustig, Sebastien" uniqKey="Lustig S" first="Sebastien" last="Lustig">Sebastien Lustig</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France. sebastien.lustig@gmail.com.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2017">2017</date>
<idno type="RBID">pubmed:28913557</idno>
<idno type="pmid">28913557</idno>
<idno type="doi">10.1007/s00264-017-3633-9</idno>
<idno type="wicri:Area/PubMed/Corpus">000071</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000071</idno>
<idno type="wicri:Area/PubMed/Curation">000071</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000071</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique.</title>
<author><name sortKey="Herry, Yannick" sort="Herry, Yannick" uniqKey="Herry Y" first="Yannick" last="Herry">Yannick Herry</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Batailler, Cecile" sort="Batailler, Cecile" uniqKey="Batailler C" first="Cécile" last="Batailler">Cécile Batailler</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Lording, Timothy" sort="Lording, Timothy" uniqKey="Lording T" first="Timothy" last="Lording">Timothy Lording</name>
<affiliation wicri:level="1"><nlm:affiliation>Melbourne Orthopaedic Group, Melbourne, VIC, Australia.</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>Melbourne Orthopaedic Group, Melbourne, VIC</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Servien, Elvire" sort="Servien, Elvire" uniqKey="Servien E" first="Elvire" last="Servien">Elvire Servien</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Neyret, Philippe" sort="Neyret, Philippe" uniqKey="Neyret P" first="Philippe" last="Neyret">Philippe Neyret</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Lustig, Sebastien" sort="Lustig, Sebastien" uniqKey="Lustig S" first="Sebastien" last="Lustig">Sebastien Lustig</name>
<affiliation wicri:level="1"><nlm:affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France. sebastien.lustig@gmail.com.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series><title level="j">International orthopaedics</title>
<idno type="eISSN">1432-5195</idno>
<imprint><date when="2017" type="published">2017</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Joint-line restitution is one objective of unicompartmental knee arthroplasty (UKA). However, the joint line is often lowered when resurfacing femoral implants are used. The aim of this study was to compare the joint-line height in UKA performed by robotic-assisted and conventional techniques.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="In-Process" Owner="NLM"><PMID Version="1">28913557</PMID>
<DateCreated><Year>2017</Year>
<Month>09</Month>
<Day>15</Day>
</DateCreated>
<DateRevised><Year>2017</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Electronic">1432-5195</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>41</Volume>
<Issue>11</Issue>
<PubDate><Year>2017</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>International orthopaedics</Title>
<ISOAbbreviation>Int Orthop</ISOAbbreviation>
</Journal>
<ArticleTitle>Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique.</ArticleTitle>
<Pagination><MedlinePgn>2265-2271</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1007/s00264-017-3633-9</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">Joint-line restitution is one objective of unicompartmental knee arthroplasty (UKA). However, the joint line is often lowered when resurfacing femoral implants are used. The aim of this study was to compare the joint-line height in UKA performed by robotic-assisted and conventional techniques.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This retrospective case-control study compared two matched groups of patients receiving a resurfacing UKA between 2013 and 2016 by either a robotic-assisted (n = 40) or conventional (n = 40) technique. Each group comprised 27 women and 13 menm wuth a mean age of 69 and 68 years, respectively. Indications for surgery were osteoarthritis (n = 35) and condylar osteonecrosis (n = 5). Two validated radiologic measurement methods were used to assess joint-line height.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Forty UKA (23 medial and 17 lateral) were analysed in each group. Restitution of joint-line height was significantly improved in the robotic-assisted group compared than the control group: +1.4 mm ±2.6 vs +4.7 mm ± 2.4 (p < 0.05) as assessed using method 1, and +1.5 mm ±2.3 vs +4.6 mm ±2.5 (p < 0.05) as assessed using method 2.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Restitution of joint-line height in resurfacing UKA can be improved with robotic-assisted surgery. Improvement in clinical outcome measures must be demonstrated with long-term studies.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Herry</LastName>
<ForeName>Yannick</ForeName>
<Initials>Y</Initials>
<AffiliationInfo><Affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Batailler</LastName>
<ForeName>Cécile</ForeName>
<Initials>C</Initials>
<AffiliationInfo><Affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Lording</LastName>
<ForeName>Timothy</ForeName>
<Initials>T</Initials>
<AffiliationInfo><Affiliation>Melbourne Orthopaedic Group, Melbourne, VIC, Australia.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Servien</LastName>
<ForeName>Elvire</ForeName>
<Initials>E</Initials>
<AffiliationInfo><Affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Neyret</LastName>
<ForeName>Philippe</ForeName>
<Initials>P</Initials>
<AffiliationInfo><Affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Lustig</LastName>
<ForeName>Sebastien</ForeName>
<Initials>S</Initials>
<AffiliationInfo><Affiliation>Centre Albert-Trillat, CHU Lyon Croix-Rousse, Hospices Civils de Lyon, 69004, Lyon, France. sebastien.lustig@gmail.com.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2017</Year>
<Month>09</Month>
<Day>14</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>Germany</Country>
<MedlineTA>Int Orthop</MedlineTA>
<NlmUniqueID>7705431</NlmUniqueID>
<ISSNLinking>0341-2695</ISSNLinking>
</MedlineJournalInfo>
<KeywordList Owner="NOTNLM"><Keyword MajorTopicYN="N">Joint line</Keyword>
<Keyword MajorTopicYN="N">Resurfacing femoral implant</Keyword>
<Keyword MajorTopicYN="N">Robotic-assisted surgery</Keyword>
<Keyword MajorTopicYN="N">Unicompartmental arthroplasty</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2017</Year>
<Month>04</Month>
<Day>02</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2017</Year>
<Month>08</Month>
<Day>28</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2017</Year>
<Month>9</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2017</Year>
<Month>9</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2017</Year>
<Month>9</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">28913557</ArticleId>
<ArticleId IdType="doi">10.1007/s00264-017-3633-9</ArticleId>
<ArticleId IdType="pii">10.1007/s00264-017-3633-9</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Asie/explor/AustralieFrV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000071 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000071 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Asie |area= AustralieFrV1 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:28913557 |texte= Improved joint-line restitution in unicompartmental knee arthroplasty using a robotic-assisted surgical technique. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:28913557" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a AustralieFrV1
This area was generated with Dilib version V0.6.33. |