Sensitivity and specificity of a portable system measuring postural tremor
Identifieur interne : 003C36 ( Main/Exploration ); précédent : 003C35; suivant : 003C37Sensitivity and specificity of a portable system measuring postural tremor
Auteurs : R. Edwards [Canada] ; A. Beuter [Canada]Source :
- Neurotoxicology and teratology [ 0892-0362 ] ; 1997.
Descripteurs français
- Pascal (Inist)
- Wicri :
- topic : Homme.
English descriptors
- KwdEn :
Abstract
A portable, accelerometric system measuring tremor was evaluated. That is, the validity and consistency of measurements as well as its ability to discriminate pathologic from physiological tremor were investigated. Control subjects and patients with Parkinson's disease were tested with this portable system and with an independent system that gave precise displacement data using lasers. It was found that amplitude of postural tremor as measured by the two systems differed significantly, but further investigation revealed that this difference was due 1) to the difference between amplitude of acceleration and amplitude of displacement, and 2) to changes in tremor over the time between tests, rather than to any inaccuracy or unreliability in the portable system. The other characteristics of tremor reported by the portable system were also valid and reasonably reliable in test-retest experiments, with the exception of the "harmonic index," which proved less stable. Most of the reported characteristics were distributed differently for the control group and for the patients with Parkinson's disease, but the large overlaps between distributions would make diagnosis difficult when tremor is not very pronounced. These results suggest that until better discriminating measures of tremor are available, tremor tests should be repeated and combined with other tests of motor function.
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PascalFrancis, to step Corpus: 000E90
- to stream PascalFrancis, to step Curation: 001033
- to stream PascalFrancis, to step Checkpoint: 000D54
- to stream Main, to step Merge: 004289
- to stream Main, to step Curation: 003C36
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Sensitivity and specificity of a portable system measuring postural tremor</title>
<author><name sortKey="Edwards, R" sort="Edwards, R" uniqKey="Edwards R" first="R." last="Edwards">R. Edwards</name>
<affiliation wicri:level="4"><inist:fA14 i1="01"><s1>Département de Kinanthropologie, Université du Québec à Montréal, C.P. 8888, succ. Centre-ville</s1>
<s2>Montréal, PQ, H3C 3P8</s2>
<s3>CAN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Canada</country>
<wicri:noRegion>Montréal, PQ, H3C 3P8</wicri:noRegion>
<orgName type="university">Université du Québec à Montréal</orgName>
<placeName><settlement type="city">Montréal</settlement>
<region type="state">Québec</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Beuter, A" sort="Beuter, A" uniqKey="Beuter A" first="A." last="Beuter">A. Beuter</name>
<affiliation wicri:level="4"><inist:fA14 i1="01"><s1>Département de Kinanthropologie, Université du Québec à Montréal, C.P. 8888, succ. Centre-ville</s1>
<s2>Montréal, PQ, H3C 3P8</s2>
<s3>CAN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Canada</country>
<wicri:noRegion>Montréal, PQ, H3C 3P8</wicri:noRegion>
<orgName type="university">Université du Québec à Montréal</orgName>
<placeName><settlement type="city">Montréal</settlement>
<region type="state">Québec</region>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">97-0282842</idno>
<date when="1997">1997</date>
<idno type="stanalyst">PASCAL 97-0282842 INIST</idno>
<idno type="RBID">Pascal:97-0282842</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000E90</idno>
<idno type="wicri:Area/PascalFrancis/Curation">001033</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000D54</idno>
<idno type="wicri:explorRef" wicri:stream="PascalFrancis" wicri:step="Checkpoint">000D54</idno>
<idno type="wicri:doubleKey">0892-0362:1997:Edwards R:sensitivity:and:specificity</idno>
<idno type="wicri:Area/Main/Merge">004289</idno>
<idno type="wicri:Area/Main/Curation">003C36</idno>
<idno type="wicri:Area/Main/Exploration">003C36</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Sensitivity and specificity of a portable system measuring postural tremor</title>
<author><name sortKey="Edwards, R" sort="Edwards, R" uniqKey="Edwards R" first="R." last="Edwards">R. Edwards</name>
<affiliation wicri:level="4"><inist:fA14 i1="01"><s1>Département de Kinanthropologie, Université du Québec à Montréal, C.P. 8888, succ. Centre-ville</s1>
<s2>Montréal, PQ, H3C 3P8</s2>
<s3>CAN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Canada</country>
<wicri:noRegion>Montréal, PQ, H3C 3P8</wicri:noRegion>
<orgName type="university">Université du Québec à Montréal</orgName>
<placeName><settlement type="city">Montréal</settlement>
<region type="state">Québec</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Beuter, A" sort="Beuter, A" uniqKey="Beuter A" first="A." last="Beuter">A. Beuter</name>
<affiliation wicri:level="4"><inist:fA14 i1="01"><s1>Département de Kinanthropologie, Université du Québec à Montréal, C.P. 8888, succ. Centre-ville</s1>
<s2>Montréal, PQ, H3C 3P8</s2>
<s3>CAN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Canada</country>
<wicri:noRegion>Montréal, PQ, H3C 3P8</wicri:noRegion>
<orgName type="university">Université du Québec à Montréal</orgName>
<placeName><settlement type="city">Montréal</settlement>
<region type="state">Québec</region>
</placeName>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Neurotoxicology and teratology</title>
<title level="j" type="abbreviated">Neurotoxicol. teratol.</title>
<idno type="ISSN">0892-0362</idno>
<imprint><date when="1997">1997</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Neurotoxicology and teratology</title>
<title level="j" type="abbreviated">Neurotoxicol. teratol.</title>
<idno type="ISSN">0892-0362</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Accelerometer</term>
<term>Human</term>
<term>Measurement</term>
<term>Measurement method</term>
<term>Parkinson disease</term>
<term>Physiological tremor</term>
<term>Portable equipment</term>
<term>Quantization</term>
<term>Sensitivity</term>
<term>Specificity</term>
<term>Validity</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Tremblement physiologique</term>
<term>Quantification</term>
<term>Mesure</term>
<term>Appareil portatif</term>
<term>Accéléromètre</term>
<term>Sensibilité</term>
<term>Spécificité</term>
<term>Validité</term>
<term>Méthode mesure</term>
<term>Parkinson maladie</term>
<term>Homme</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A portable, accelerometric system measuring tremor was evaluated. That is, the validity and consistency of measurements as well as its ability to discriminate pathologic from physiological tremor were investigated. Control subjects and patients with Parkinson's disease were tested with this portable system and with an independent system that gave precise displacement data using lasers. It was found that amplitude of postural tremor as measured by the two systems differed significantly, but further investigation revealed that this difference was due 1) to the difference between amplitude of acceleration and amplitude of displacement, and 2) to changes in tremor over the time between tests, rather than to any inaccuracy or unreliability in the portable system. The other characteristics of tremor reported by the portable system were also valid and reasonably reliable in test-retest experiments, with the exception of the "harmonic index," which proved less stable. Most of the reported characteristics were distributed differently for the control group and for the patients with Parkinson's disease, but the large overlaps between distributions would make diagnosis difficult when tremor is not very pronounced. These results suggest that until better discriminating measures of tremor are available, tremor tests should be repeated and combined with other tests of motor function.</div>
</front>
</TEI>
<affiliations><list><country><li>Canada</li>
</country>
<region><li>Québec</li>
</region>
<settlement><li>Montréal</li>
</settlement>
<orgName><li>Université du Québec à Montréal</li>
</orgName>
</list>
<tree><country name="Canada"><region name="Québec"><name sortKey="Edwards, R" sort="Edwards, R" uniqKey="Edwards R" first="R." last="Edwards">R. Edwards</name>
</region>
<name sortKey="Beuter, A" sort="Beuter, A" uniqKey="Beuter A" first="A." last="Beuter">A. Beuter</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Canada/explor/ParkinsonCanadaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003C36 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003C36 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Canada |area= ParkinsonCanadaV1 |flux= Main |étape= Exploration |type= RBID |clé= Pascal:97-0282842 |texte= Sensitivity and specificity of a portable system measuring postural tremor }}
![]() | This area was generated with Dilib version V0.6.29. | ![]() |