The measurement of tremor using a velocity transducer: comparison to simultaneous recordings using transducers of displacement, acceleration and muscle activity
Identifieur interne : 003694 ( Main/Exploration ); précédent : 003693; suivant : 003695The measurement of tremor using a velocity transducer: comparison to simultaneous recordings using transducers of displacement, acceleration and muscle activity
Auteurs : Kathleen E. Norman [Canada] ; Roderick Edwards [Canada] ; Anne Beuter [Canada]Source :
- Journal of Neuroscience Methods [ 0165-0270 ] ; 1999.
Descripteurs français
- Pascal (Inist)
- Wicri :
- topic : Homme.
English descriptors
- KwdEn :
- Acceleration, Adult, Aged, Biomechanical Phenomena, Body movement, Case-Control Studies, Displacement, EMG, Electromyography, Electromyography (instrumentation), Electromyography (methods), Female, Fingers (physiology), Human, Humans, Lasers, Male, Measurement method, Middle Aged, Muscle contraction, Parkinson Disease (diagnosis), Parkinson disease, Parkinson’s disease, Transducers, Tremor, Tremor (diagnosis), Velocity.
- MESH :
- diagnosis : Parkinson Disease, Tremor.
- instrumentation : Electromyography.
- methods : Electromyography.
- physiology : Fingers.
- Acceleration, Adult, Aged, Biomechanical Phenomena, Case-Control Studies, Female, Humans, Lasers, Male, Middle Aged, Transducers.
Abstract
Precise kinematic measurements of tremor have historically been obtained using accelerometers. However, current technology permits precise measurements in velocity and displacement. The primary advantage of velocity recording is that only one step of integration or differentiation is required for either displacement or acceleration. A method is presented of measuring finger tremor using a laser system that transduces velocity precisely. Measurements of postural finger tremor thus obtained were compared to those simultaneously obtained from a laser system that transduces displacement, from an accelerometer and from surface electromyography (EMG) of the extensor digitorum communis. A range of amplitude and frequency content was obtained by testing control subjects and subjects with Parkinson’s disease. The velocity transducer showed excellent correspondence of amplitude and frequency measurement with the displacement transducer. Measures of absolute and relative amplitude correlated well (r≥0.96 in amplitude measures in displacement, velocity and acceleration), and high coherence was found throughout the frequency range of interest. Measurements by the accelerometer generally showed poorer correspondence with those of the other instruments. EMG measurements showed good correspondence in some trials but poorer correspondence in others, attributed to the low level of muscle activity required in the task. Precise kinematic measurements appear to be highly sensitive to neuromotor impairment.
Url:
DOI: 10.1016/S0165-0270(99)00091-6
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 001F98
- to stream Istex, to step Curation: 001F98
- to stream Istex, to step Checkpoint: 001333
- to stream Main, to step Merge: 003C73
- to stream PascalFrancis, to step Corpus: 000D25
- to stream PascalFrancis, to step Curation: 001198
- to stream PascalFrancis, to step Checkpoint: 000C20
- to stream Main, to step Merge: 003D73
- to stream PubMed, to step Corpus: 001678
- to stream PubMed, to step Curation: 001678
- to stream PubMed, to step Checkpoint: 001678
- to stream Ncbi, to step Merge: 000065
- to stream Ncbi, to step Curation: 000065
- to stream Ncbi, to step Checkpoint: 000065
- to stream Main, to step Merge: 003B56
- to stream Main, to step Curation: 003694
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">The measurement of tremor using a velocity transducer: comparison to simultaneous recordings using transducers of displacement, acceleration and muscle activity</title>
<author><name sortKey="Norman, Kathleen E" sort="Norman, Kathleen E" uniqKey="Norman K" first="Kathleen E" last="Norman">Kathleen E. Norman</name>
</author>
<author><name sortKey="Edwards, Roderick" sort="Edwards, Roderick" uniqKey="Edwards R" first="Roderick" last="Edwards">Roderick Edwards</name>
</author>
<author><name sortKey="Beuter, Anne" sort="Beuter, Anne" uniqKey="Beuter A" first="Anne" last="Beuter">Anne Beuter</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:289DFACCD774CCDA3E169B7E6CE12541639047AF</idno>
<date when="1999" year="1999">1999</date>
<idno type="doi">10.1016/S0165-0270(99)00091-6</idno>
<idno type="url">https://api-v5.istex.fr/document/289DFACCD774CCDA3E169B7E6CE12541639047AF/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001F98</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001F98</idno>
<idno type="wicri:Area/Istex/Curation">001F98</idno>
<idno type="wicri:Area/Istex/Checkpoint">001333</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001333</idno>
<idno type="wicri:doubleKey">0165-0270:1999:Norman K:the:measurement:of</idno>
<idno type="wicri:Area/Main/Merge">003C73</idno>
<idno type="wicri:source">INIST</idno>
<idno type="RBID">Pascal:99-0549312</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000D25</idno>
<idno type="wicri:Area/PascalFrancis/Curation">001198</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000C20</idno>
<idno type="wicri:explorRef" wicri:stream="PascalFrancis" wicri:step="Checkpoint">000C20</idno>
<idno type="wicri:doubleKey">0165-0270:1999:Norman K:the:measurement:of</idno>
<idno type="wicri:Area/Main/Merge">003D73</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:10595702</idno>
<idno type="wicri:Area/PubMed/Corpus">001678</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001678</idno>
<idno type="wicri:Area/PubMed/Curation">001678</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">001678</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001678</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">001678</idno>
<idno type="wicri:Area/Ncbi/Merge">000065</idno>
<idno type="wicri:Area/Ncbi/Curation">000065</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000065</idno>
<idno type="wicri:doubleKey">0165-0270:1999:Norman K:the:measurement:of</idno>
<idno type="wicri:Area/Main/Merge">003B56</idno>
<idno type="wicri:Area/Main/Curation">003694</idno>
<idno type="wicri:Area/Main/Exploration">003694</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">The measurement of tremor using a velocity transducer: comparison to simultaneous recordings using transducers of displacement, acceleration and muscle activity</title>
<author><name sortKey="Norman, Kathleen E" sort="Norman, Kathleen E" uniqKey="Norman K" first="Kathleen E" last="Norman">Kathleen E. Norman</name>
<affiliation wicri:level="4"><country>Canada</country>
<wicri:regionArea>Laboratoire de neuroscience de la cognition (LNC), Université du Québec à Montréal (UQAM), C.P. 8888, succursale centre-ville, Montréal, Québec</wicri:regionArea>
<orgName type="university">Université du Québec à Montréal</orgName>
<placeName><settlement type="city">Montréal</settlement>
<region type="state">Québec</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Edwards, Roderick" sort="Edwards, Roderick" uniqKey="Edwards R" first="Roderick" last="Edwards">Roderick Edwards</name>
<affiliation wicri:level="4"><country>Canada</country>
<wicri:regionArea>Laboratoire de neuroscience de la cognition (LNC), Université du Québec à Montréal (UQAM), C.P. 8888, succursale centre-ville, Montréal, Québec</wicri:regionArea>
<orgName type="university">Université du Québec à Montréal</orgName>
<placeName><settlement type="city">Montréal</settlement>
<region type="state">Québec</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Beuter, Anne" sort="Beuter, Anne" uniqKey="Beuter A" first="Anne" last="Beuter">Anne Beuter</name>
<affiliation wicri:level="4"><country>Canada</country>
<wicri:regionArea>Laboratoire de neuroscience de la cognition (LNC), Université du Québec à Montréal (UQAM), C.P. 8888, succursale centre-ville, Montréal, Québec</wicri:regionArea>
<orgName type="university">Université du Québec à Montréal</orgName>
<placeName><settlement type="city">Montréal</settlement>
<region type="state">Québec</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Journal of Neuroscience Methods</title>
<title level="j" type="abbrev">NSM</title>
<idno type="ISSN">0165-0270</idno>
<imprint><publisher>ELSEVIER</publisher>
<date type="published" when="1999">1999</date>
<biblScope unit="volume">92</biblScope>
<biblScope unit="issue">1–2</biblScope>
<biblScope unit="page" from="41">41</biblScope>
<biblScope unit="page" to="54">54</biblScope>
</imprint>
<idno type="ISSN">0165-0270</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0165-0270</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acceleration</term>
<term>Adult</term>
<term>Aged</term>
<term>Biomechanical Phenomena</term>
<term>Body movement</term>
<term>Case-Control Studies</term>
<term>Displacement</term>
<term>EMG</term>
<term>Electromyography</term>
<term>Electromyography (instrumentation)</term>
<term>Electromyography (methods)</term>
<term>Female</term>
<term>Fingers (physiology)</term>
<term>Human</term>
<term>Humans</term>
<term>Lasers</term>
<term>Male</term>
<term>Measurement method</term>
<term>Middle Aged</term>
<term>Muscle contraction</term>
<term>Parkinson Disease (diagnosis)</term>
<term>Parkinson disease</term>
<term>Parkinson’s disease</term>
<term>Transducers</term>
<term>Tremor</term>
<term>Tremor (diagnosis)</term>
<term>Velocity</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en"><term>Parkinson Disease</term>
<term>Tremor</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Electromyography</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Electromyography</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en"><term>Fingers</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Acceleration</term>
<term>Adult</term>
<term>Aged</term>
<term>Biomechanical Phenomena</term>
<term>Case-Control Studies</term>
<term>Female</term>
<term>Humans</term>
<term>Lasers</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Transducers</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Accélération</term>
<term>Contraction musculaire</term>
<term>Electromyographie</term>
<term>Homme</term>
<term>Mouvement corporel</term>
<term>Méthode mesure</term>
<term>Parkinson maladie</term>
<term>Tremblement</term>
<term>Vitesse</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Homme</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Precise kinematic measurements of tremor have historically been obtained using accelerometers. However, current technology permits precise measurements in velocity and displacement. The primary advantage of velocity recording is that only one step of integration or differentiation is required for either displacement or acceleration. A method is presented of measuring finger tremor using a laser system that transduces velocity precisely. Measurements of postural finger tremor thus obtained were compared to those simultaneously obtained from a laser system that transduces displacement, from an accelerometer and from surface electromyography (EMG) of the extensor digitorum communis. A range of amplitude and frequency content was obtained by testing control subjects and subjects with Parkinson’s disease. The velocity transducer showed excellent correspondence of amplitude and frequency measurement with the displacement transducer. Measures of absolute and relative amplitude correlated well (r≥0.96 in amplitude measures in displacement, velocity and acceleration), and high coherence was found throughout the frequency range of interest. Measurements by the accelerometer generally showed poorer correspondence with those of the other instruments. EMG measurements showed good correspondence in some trials but poorer correspondence in others, attributed to the low level of muscle activity required in the task. Precise kinematic measurements appear to be highly sensitive to neuromotor impairment.</div>
</front>
</TEI>
<affiliations><list><country><li>Canada</li>
</country>
<region><li>Québec</li>
</region>
<settlement><li>Montréal</li>
</settlement>
<orgName><li>Université du Québec à Montréal</li>
</orgName>
</list>
<tree><country name="Canada"><region name="Québec"><name sortKey="Norman, Kathleen E" sort="Norman, Kathleen E" uniqKey="Norman K" first="Kathleen E" last="Norman">Kathleen E. Norman</name>
</region>
<name sortKey="Beuter, Anne" sort="Beuter, Anne" uniqKey="Beuter A" first="Anne" last="Beuter">Anne Beuter</name>
<name sortKey="Edwards, Roderick" sort="Edwards, Roderick" uniqKey="Edwards R" first="Roderick" last="Edwards">Roderick Edwards</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Canada/explor/ParkinsonCanadaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003694 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003694 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Canada |area= ParkinsonCanadaV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:289DFACCD774CCDA3E169B7E6CE12541639047AF |texte= The measurement of tremor using a velocity transducer: comparison to simultaneous recordings using transducers of displacement, acceleration and muscle activity }}
This area was generated with Dilib version V0.6.29. |