Precision study of DXA‐based patient‐specific finite element modeling for assessing hip fracture risk
Identifieur interne : 000F57 ( Main/Exploration ); précédent : 000F56; suivant : 000F58Precision study of DXA‐based patient‐specific finite element modeling for assessing hip fracture risk
Auteurs : Yunhua Luo [Canada, République populaire de Chine] ; Zannatul Ferdous [Canada] ; William D. Leslie [Canada]Source :
- International Journal for Numerical Methods in Biomedical Engineering [ 2040-7939 ] ; 2013-05.
Abstract
Finite element (FE) modeling based on a patient's hip dual energy X‐ray absorptiometry (DXA) image is a promising tool for more accurately assessing hip fracture risk, as it is able to comprehensively consider effects from all the mechanical parameters affecting hip fracture. However, a number of factors influence the precision (also known as repeatability or reproducibility) of a DXA‐based FE procedure, for example, subject positioning in DXA scanning. As a procedure is required to have adequately high precision in clinical application, we investigated the effects of the involved factors on the precision of a DXA‐based patient‐specific FE procedure developed by the authors, to provide insight into how the precision of the procedure can be improved so that it can meet the clinical standards. Fracture risk indices corresponding to initial and repeat DXA scans acquired in 30 typical clinical subjects were computed and compared to assess short term repeatability of the procedure. It was found that inconsistent positioning followed by manual segmentation of the projected femur contour induced significant variability in the predicted fracture risk indices. This research suggests that, to apply the DXA‐based FE procedure in clinical assessment, it will be necessary to pay more strict attention to subject positioning in DXA scanning. Copyright © 2013 John Wiley & Sons, Ltd.
Url:
DOI: 10.1002/cnm.2548
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 001A30
- to stream Istex, to step Curation: 001A30
- to stream Istex, to step Checkpoint: 000075
- to stream Main, to step Merge: 000F69
- to stream Main, to step Curation: 000F57
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Precision study of DXA‐based patient‐specific finite element modeling for assessing hip fracture risk</title>
<author><name sortKey="Luo, Yunhua" sort="Luo, Yunhua" uniqKey="Luo Y" first="Yunhua" last="Luo">Yunhua Luo</name>
</author>
<author><name sortKey="Ferdous, Zannatul" sort="Ferdous, Zannatul" uniqKey="Ferdous Z" first="Zannatul" last="Ferdous">Zannatul Ferdous</name>
</author>
<author><name sortKey="Leslie, William D" sort="Leslie, William D" uniqKey="Leslie W" first="William D." last="Leslie">William D. Leslie</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:79D1031B03652A3845163692366FC2073F428EFD</idno>
<date when="2013" year="2013">2013</date>
<idno type="doi">10.1002/cnm.2548</idno>
<idno type="url">https://api-v5.istex.fr/document/79D1031B03652A3845163692366FC2073F428EFD/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001A30</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001A30</idno>
<idno type="wicri:Area/Istex/Curation">001A30</idno>
<idno type="wicri:Area/Istex/Checkpoint">000075</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000075</idno>
<idno type="wicri:doubleKey">2040-7939:2013:Luo Y:precision:study:of</idno>
<idno type="wicri:Area/Main/Merge">000F69</idno>
<idno type="wicri:Area/Main/Curation">000F57</idno>
<idno type="wicri:Area/Main/Exploration">000F57</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Precision study of DXA‐based patient‐specific finite element modeling for assessing hip fracture risk</title>
<author><name sortKey="Luo, Yunhua" sort="Luo, Yunhua" uniqKey="Luo Y" first="Yunhua" last="Luo">Yunhua Luo</name>
<affiliation wicri:level="4"><country xml:lang="fr">Canada</country>
<wicri:regionArea>Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 2N2</wicri:regionArea>
<orgName type="university">Université du Manitoba</orgName>
<placeName><settlement type="city">Winnipeg</settlement>
<region type="state">Manitoba</region>
</placeName>
</affiliation>
<affiliation wicri:level="3"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Anatomy, Southern Medical University, 510515, Guangzhou</wicri:regionArea>
<placeName><settlement type="city">Jiangmen</settlement>
<region type="province">Guangdong</region>
</placeName>
</affiliation>
<affiliation></affiliation>
<affiliation wicri:level="1"><country wicri:rule="url">Canada</country>
</affiliation>
</author>
<author><name sortKey="Ferdous, Zannatul" sort="Ferdous, Zannatul" uniqKey="Ferdous Z" first="Zannatul" last="Ferdous">Zannatul Ferdous</name>
<affiliation wicri:level="4"><country xml:lang="fr">Canada</country>
<wicri:regionArea>Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, University of Manitoba, MB R3T 2N2, Winnipeg</wicri:regionArea>
<orgName type="university">Université du Manitoba</orgName>
<placeName><settlement type="city">Winnipeg</settlement>
<region type="state">Manitoba</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Leslie, William D" sort="Leslie, William D" uniqKey="Leslie W" first="William D." last="Leslie">William D. Leslie</name>
<affiliation wicri:level="4"><country xml:lang="fr">Canada</country>
<wicri:regionArea>Department of Radiology, Faculty of Medicine, University of Manitoba, Winnipeg, MB R2H 2A6</wicri:regionArea>
<orgName type="university">Université du Manitoba</orgName>
<placeName><settlement type="city">Winnipeg</settlement>
<region type="state">Manitoba</region>
</placeName>
</affiliation>
<affiliation wicri:level="4"><country xml:lang="fr">Canada</country>
<wicri:regionArea>Department of Internal Medicine, Faculty of Medicine, University of Manitoba, MB R2H 2A6, Winnipeg</wicri:regionArea>
<orgName type="university">Université du Manitoba</orgName>
<placeName><settlement type="city">Winnipeg</settlement>
<region type="state">Manitoba</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">International Journal for Numerical Methods in Biomedical Engineering</title>
<title level="j" type="abbrev">Int. J. Numer. Meth. Biomed. Engng.</title>
<idno type="ISSN">2040-7939</idno>
<idno type="eISSN">2040-7947</idno>
<imprint><publisher>Blackwell Publishing Ltd</publisher>
<date type="published" when="2013-05">2013-05</date>
<biblScope unit="volume">29</biblScope>
<biblScope unit="issue">5</biblScope>
<biblScope unit="page" from="615">615</biblScope>
<biblScope unit="page" to="629">629</biblScope>
</imprint>
<idno type="ISSN">2040-7939</idno>
</series>
<idno type="istex">79D1031B03652A3845163692366FC2073F428EFD</idno>
<idno type="DOI">10.1002/cnm.2548</idno>
<idno type="ArticleID">CNM2548</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">2040-7939</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract">Finite element (FE) modeling based on a patient's hip dual energy X‐ray absorptiometry (DXA) image is a promising tool for more accurately assessing hip fracture risk, as it is able to comprehensively consider effects from all the mechanical parameters affecting hip fracture. However, a number of factors influence the precision (also known as repeatability or reproducibility) of a DXA‐based FE procedure, for example, subject positioning in DXA scanning. As a procedure is required to have adequately high precision in clinical application, we investigated the effects of the involved factors on the precision of a DXA‐based patient‐specific FE procedure developed by the authors, to provide insight into how the precision of the procedure can be improved so that it can meet the clinical standards. Fracture risk indices corresponding to initial and repeat DXA scans acquired in 30 typical clinical subjects were computed and compared to assess short term repeatability of the procedure. It was found that inconsistent positioning followed by manual segmentation of the projected femur contour induced significant variability in the predicted fracture risk indices. This research suggests that, to apply the DXA‐based FE procedure in clinical assessment, it will be necessary to pay more strict attention to subject positioning in DXA scanning. Copyright © 2013 John Wiley & Sons, Ltd.</div>
</front>
</TEI>
<affiliations><list><country><li>Canada</li>
<li>République populaire de Chine</li>
</country>
<region><li>Guangdong</li>
<li>Manitoba</li>
</region>
<settlement><li>Jiangmen</li>
<li>Winnipeg</li>
</settlement>
<orgName><li>Université du Manitoba</li>
</orgName>
</list>
<tree><country name="Canada"><region name="Manitoba"><name sortKey="Luo, Yunhua" sort="Luo, Yunhua" uniqKey="Luo Y" first="Yunhua" last="Luo">Yunhua Luo</name>
</region>
<name sortKey="Ferdous, Zannatul" sort="Ferdous, Zannatul" uniqKey="Ferdous Z" first="Zannatul" last="Ferdous">Zannatul Ferdous</name>
<name sortKey="Leslie, William D" sort="Leslie, William D" uniqKey="Leslie W" first="William D." last="Leslie">William D. Leslie</name>
<name sortKey="Leslie, William D" sort="Leslie, William D" uniqKey="Leslie W" first="William D." last="Leslie">William D. Leslie</name>
<name sortKey="Luo, Yunhua" sort="Luo, Yunhua" uniqKey="Luo Y" first="Yunhua" last="Luo">Yunhua Luo</name>
</country>
<country name="République populaire de Chine"><region name="Guangdong"><name sortKey="Luo, Yunhua" sort="Luo, Yunhua" uniqKey="Luo Y" first="Yunhua" last="Luo">Yunhua Luo</name>
</region>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Canada/explor/ParkinsonCanadaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F57 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000F57 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Canada |area= ParkinsonCanadaV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:79D1031B03652A3845163692366FC2073F428EFD |texte= Precision study of DXA‐based patient‐specific finite element modeling for assessing hip fracture risk }}
This area was generated with Dilib version V0.6.29. |