Evaluation using GEANT4 of the transit dose in the Tunisian gamma irradiator for insect sterilization.
Identifieur interne : 000063 ( PubMed/Corpus ); précédent : 000062; suivant : 000064Evaluation using GEANT4 of the transit dose in the Tunisian gamma irradiator for insect sterilization.
Auteurs : K. Mannai ; B. Askri ; A. Loussaief ; A. TrabelsiSource :
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [ 0969-8043 ] ; 2007.
English descriptors
- KwdEn :
- MESH :
- chemical : Cobalt Radioisotopes.
- geographic : Tunisia.
- instrumentation : Pest Control, Biological.
- methods : Pest Control, Biological.
- radiation effects : Insects.
- Animals, Gamma Rays, Radiation Dosage.
Abstract
A simulation study of the Tunisian Gamma Irradiation Facility for sterile insects release programs has been realized using the GEANT4 Monte Carlo code of CERN. The dose was calculated and measured for high and low dose values inside the irradiation cell. The calculated high dose was in good agreement with measurements. However, a discrepancy between calculated and measured values occurs at dose levels commonly used for sterilization of insects. We argue that this discrepancy is due to the transit dose absorbed during displacement of targets from their initial position towards their irradiation position and displacement of radiation source pencils from storage towards their irradiation position. The discrepancy is corrected by taking into account the transit dose.
DOI: 10.1016/j.apradiso.2007.01.011
PubMed: 17395474
Links to Exploration step
pubmed:17395474Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Evaluation using GEANT4 of the transit dose in the Tunisian gamma irradiator for insect sterilization.</title>
<author><name sortKey="Mannai, K" sort="Mannai, K" uniqKey="Mannai K" first="K" last="Mannai">K. Mannai</name>
<affiliation><nlm:affiliation>Unité de Recherche de Physique Nucléaire et des Hautes énergies, Département de Physique, Faculté des Sciences de Tunis, El-Manar 2092, Tunisia.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Askri, B" sort="Askri, B" uniqKey="Askri B" first="B" last="Askri">B. Askri</name>
</author>
<author><name sortKey="Loussaief, A" sort="Loussaief, A" uniqKey="Loussaief A" first="A" last="Loussaief">A. Loussaief</name>
</author>
<author><name sortKey="Trabelsi, A" sort="Trabelsi, A" uniqKey="Trabelsi A" first="A" last="Trabelsi">A. Trabelsi</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2007">2007</date>
<idno type="RBID">pubmed:17395474</idno>
<idno type="pmid">17395474</idno>
<idno type="doi">10.1016/j.apradiso.2007.01.011</idno>
<idno type="wicri:Area/PubMed/Corpus">000063</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000063</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Evaluation using GEANT4 of the transit dose in the Tunisian gamma irradiator for insect sterilization.</title>
<author><name sortKey="Mannai, K" sort="Mannai, K" uniqKey="Mannai K" first="K" last="Mannai">K. Mannai</name>
<affiliation><nlm:affiliation>Unité de Recherche de Physique Nucléaire et des Hautes énergies, Département de Physique, Faculté des Sciences de Tunis, El-Manar 2092, Tunisia.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Askri, B" sort="Askri, B" uniqKey="Askri B" first="B" last="Askri">B. Askri</name>
</author>
<author><name sortKey="Loussaief, A" sort="Loussaief, A" uniqKey="Loussaief A" first="A" last="Loussaief">A. Loussaief</name>
</author>
<author><name sortKey="Trabelsi, A" sort="Trabelsi, A" uniqKey="Trabelsi A" first="A" last="Trabelsi">A. Trabelsi</name>
</author>
</analytic>
<series><title level="j">Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine</title>
<idno type="ISSN">0969-8043</idno>
<imprint><date when="2007" type="published">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Animals</term>
<term>Cobalt Radioisotopes</term>
<term>Gamma Rays</term>
<term>Insects (radiation effects)</term>
<term>Pest Control, Biological (instrumentation)</term>
<term>Pest Control, Biological (methods)</term>
<term>Radiation Dosage</term>
<term>Tunisia</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Cobalt Radioisotopes</term>
</keywords>
<keywords scheme="MESH" type="geographic" xml:lang="en"><term>Tunisia</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Pest Control, Biological</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Pest Control, Biological</term>
</keywords>
<keywords scheme="MESH" qualifier="radiation effects" xml:lang="en"><term>Insects</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Animals</term>
<term>Gamma Rays</term>
<term>Radiation Dosage</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A simulation study of the Tunisian Gamma Irradiation Facility for sterile insects release programs has been realized using the GEANT4 Monte Carlo code of CERN. The dose was calculated and measured for high and low dose values inside the irradiation cell. The calculated high dose was in good agreement with measurements. However, a discrepancy between calculated and measured values occurs at dose levels commonly used for sterilization of insects. We argue that this discrepancy is due to the transit dose absorbed during displacement of targets from their initial position towards their irradiation position and displacement of radiation source pencils from storage towards their irradiation position. The discrepancy is corrected by taking into account the transit dose.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">17395474</PMID>
<DateCreated><Year>2007</Year>
<Month>4</Month>
<Day>13</Day>
</DateCreated>
<DateCompleted><Year>2007</Year>
<Month>06</Month>
<Day>21</Day>
</DateCompleted>
<DateRevised><Year>2007</Year>
<Month>4</Month>
<Day>13</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Print">0969-8043</ISSN>
<JournalIssue CitedMedium="Print"><Volume>65</Volume>
<Issue>6</Issue>
<PubDate><Year>2007</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine</Title>
<ISOAbbreviation>Appl Radiat Isot</ISOAbbreviation>
</Journal>
<ArticleTitle>Evaluation using GEANT4 of the transit dose in the Tunisian gamma irradiator for insect sterilization.</ArticleTitle>
<Pagination><MedlinePgn>701-7</MedlinePgn>
</Pagination>
<Abstract><AbstractText>A simulation study of the Tunisian Gamma Irradiation Facility for sterile insects release programs has been realized using the GEANT4 Monte Carlo code of CERN. The dose was calculated and measured for high and low dose values inside the irradiation cell. The calculated high dose was in good agreement with measurements. However, a discrepancy between calculated and measured values occurs at dose levels commonly used for sterilization of insects. We argue that this discrepancy is due to the transit dose absorbed during displacement of targets from their initial position towards their irradiation position and displacement of radiation source pencils from storage towards their irradiation position. The discrepancy is corrected by taking into account the transit dose.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Mannai</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
<AffiliationInfo><Affiliation>Unité de Recherche de Physique Nucléaire et des Hautes énergies, Département de Physique, Faculté des Sciences de Tunis, El-Manar 2092, Tunisia.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Askri</LastName>
<ForeName>B</ForeName>
<Initials>B</Initials>
</Author>
<Author ValidYN="Y"><LastName>Loussaief</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y"><LastName>Trabelsi</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
</Author>
</AuthorList>
<Language>ENG</Language>
<PublicationTypeList><PublicationType UI="D023362">Evaluation Studies</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2007</Year>
<Month>Feb</Month>
<Day>06</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>England</Country>
<MedlineTA>Appl Radiat Isot</MedlineTA>
<NlmUniqueID>9306253</NlmUniqueID>
<ISSNLinking>0969-8043</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003037">Cobalt Radioisotopes</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000818" MajorTopicYN="N">Animals</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003037" MajorTopicYN="N">Cobalt Radioisotopes</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D005720" MajorTopicYN="N">Gamma Rays</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007313" MajorTopicYN="N">Insects</DescriptorName>
<QualifierName UI="Q000528" MajorTopicYN="Y">radiation effects</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D010572" MajorTopicYN="N">Pest Control, Biological</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011829" MajorTopicYN="N">Radiation Dosage</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014416" MajorTopicYN="N" Type="Geographic">Tunisia</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2006</Year>
<Month>5</Month>
<Day>3</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised"><Year>2006</Year>
<Month>10</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2007</Year>
<Month>1</Month>
<Day>9</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2007</Year>
<Month>3</Month>
<Day>31</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2007</Year>
<Month>6</Month>
<Day>22</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2007</Year>
<Month>3</Month>
<Day>31</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">17395474</ArticleId>
<ArticleId IdType="pii">S0969-8043(07)00032-2</ArticleId>
<ArticleId IdType="doi">10.1016/j.apradiso.2007.01.011</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/CobaltMaghrebV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000063 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000063 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Terre |area= CobaltMaghrebV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:17395474 |texte= Evaluation using GEANT4 of the transit dose in the Tunisian gamma irradiator for insect sterilization. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:17395474" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a CobaltMaghrebV1
This area was generated with Dilib version V0.6.32. |